0

RTD WIRE FEP

RTD WIRE FEP
RTD WIRE FEP
Price And Quantity
  • 100
  • Meter/Meters
    Product Specifications
    • RTD CABLES
    • FEP
    • Transmit signal from RTD Sensor to Control Unit
    • Manufacturing of RTD Sensor & as an extension wires from RTD Sensors to control unit
    • 100 Meter (m)
    Product Description

    RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

     ELTEC PTFE Insulated RTD Extension wires conforms to US Military 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.

    HV TEST

    GRADE

    SPARK TESTING

    DIE ELECTRIC TESTING

    ET (250 V)

    2500 V AC

    1500 V AC

    E (600 V)

    3400 V AC

    2000 V AC

    EE (1000 V)

    5000 V AC

    3000 V AC

     

    APPLICATIONS

    PRODUCT FEATURES

    RTD Sensors & Extension Wires

        Continuous use up to 200 oC

    RTD Autoclave

           Single exposure up to 400oC

    Medical Instruments & Scientific Equipments

     Chemical Resistant

    Sensors, Load Cells & Pressure Transducers

     Moisture Resistant

    Electronics & Communication Equipment

      Flame Retardant

       Process Instrumentation

      Smoother surface finish

        Packaging

    Good Electrical Properties

     

    PRODUCT  SPECIFICATIONS:

    Conductor

    Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 51034, Refer Table for most popular & standard wire sizes.

    Core Insulation

    Flame Retardant extruded  FEP

    No. of Cores

    2, 4, 6, 8 or even more

    Construction

    Twisted Conductor

    Outer Sheath

    Flame Retardant extruded FEP

    SS  JACKET

    Optional Outside SS Metal braid

    Color Coding

    Confirms to EN 60751

      Other sizes in SWG and also different construction in other stranded sizes are available on request

      Optional construction of twisted conductors & shielding

      Duplex construction are also available


    FEW POPULAR RTD CABLE WIRE SIZES as per MIL  16878

     

    Sr. No.

    Size in AWG

    No. of strands/dia. of each strand (mm)

    Parameters of conductor (Nominal)
    (As per JSS 51034)

    Nominal Dia. of Insulated Wire

    Dia. (mm)

    Cross section (sq. mm)

    Resistance Ohm/km at     ° C

    Elongation % (Min)

    ET
    (250 V) AC

    E
    (600 V ) AC

    EE
    (1000 V) AC

     

    1.

    26/7/34

    7/0.16

    0.48

    0.1409

    133.7

    9.0

    0.79

    0.99

    1.24

     

    2.

    24/7/32

    7/0.2

    0.60

    0.2270

    83.2

    9.0

    0.91

    1.12

    1.37

     

    3.

    24/19/36

    19/0.13

    0.63

    0.2407

    80.2

    9.0

    0.91

    1.12

    1.37

     

    4.

    22/7/30

    7/0.25

    0.75

    0.3547

    52.5

    13.5

    1.07

    1.27

    1.52

     

    5.

    22/19/34

    19/0.16

    0.80

    0.3820

    49.8

    9.0

    1.07

    1.27

    1.52

     

    6.

    20/7/28

    7/0.32

    0.97

    0.5630

    33.0

    13.5

    1.27

    1.47

    1.73

     

    7.

    20/19/32

    19/0.2

    1.00

    0.6162

    30.3

    9.0

    1.27

    1.47

    1.73

     

      

      

    Trade Information
    • Yes
    • Free samples are available
    • 100 Mtrs. / 200 Mtrs. coil 500 Mtrs. on plastic spool 1000 Mtrs. on wooden drums
    • Asia, Australia, Central America, North America, South America, Middle East, Africa
    • All India
    • CE & ISO 9001:2015 CE
      Contact Us

      No. 16, Bhaktinagar, Station Plot, Rajkot, Gujarat, 360002, India
      Phone :+918068093909